stream results for HP N4000, 1 cpu

From: Kirby Collins (kcollins@rsn.hp.com)
Date: Wed May 12 1999 - 13:40:40 CDT


run on a prerelease of HP-UX 11.0 March 1999 Extension Pack
compiled with HP Fortran 90 Compiler B.11.01.06
f90 -o stream_d.mp +DA2.0 +DS2.0 +O3 +Odataprefetch +FPD -Wl,+pd,64M
+Oparallel stream_d.f second_wall.o

----------------------------------------------
 Double precision appears to have 16 digits of accuracy
 Assuming 8 bytes per DOUBLE PRECISION word
----------------------------------------------
 Array size = 20000000
 Offset = 0
 The total memory requirement is 457 MB
 You are running each test 10 times
 The *best* time for each test is used
 ----------------------------------------------------
 Your clock granularity/precision appears to be 3 microseconds
 The tests below will each take a time on the order
 of 271725 microseconds
    (= 90575 clock ticks)
 Increase the size of the arrays if this shows that
 you are not getting at least 20 clock ticks per test.
 ----------------------------------------------------
 WARNING -- The above is only a rough guideline.
 For best results, please be sure you know the
 precision of your system timer.
 ----------------------------------------------------
Function Rate (MB/s) RMS time Min time Max time
Copy: 759.9506 0.4212 0.4211 0.4216
Scale: 758.6967 0.4220 0.4218 0.4226
Add: 834.5851 0.5756 0.5751 0.5770
Triad: 836.1392 0.5743 0.5741 0.5749
 Sum of a is = 2.306601562980265E+19
 Sum of b is = 4.613203126278327E+18
 Sum of c is = 6.150937498077968E+18



This archive was generated by hypermail 2b29 : Tue Apr 18 2000 - 05:23:08 CDT