Hi,
just came across your STREAM benchmark and had to try it on my new G4 "Quicksilver" - I'm not sure how much you're still actively interested in current results, since the ones posted on your web site don't show more recent machines, but here they are anyway :)
I'm quoting the results in the alphabetical order the different Mac versions of the benchmark suite are located in the folder. Do you have a theory why the 601 optimized version of the benchmark performs so much better (>70%!) than the rest? The G4/867 has 256kB of 2nd level cache and 2MB of 3rd level cache, but that shouldn't make any difference since the test data doesn't fit completely in either. Interesting...
yours
Stefan Hänßgen
-------------------------------------------------------------
This system uses 8 bytes per DOUBLE PRECISION word.
-------------------------------------------------------------
Array size = 400000, Offset = 0
Total memory required = 9.2 MB.
Each test is run 10 times, but only
the *best* time for each is used.
-------------------------------------------------------------
Your clock granularity/precision appears to be 1 microseconds.
Each test below will take on the order of 16257 microseconds.
(= 16257 clock ticks)
Increase the size of the arrays if this shows that
you are not getting at least 20 clock ticks per test.
-------------------------------------------------------------
WARNING -- The above is only a rough guideline.
For best results, please be sure you know the
precision of your system timer.
-------------------------------------------------------------
Function Rate (MB/s) RMS time Min time Max time
Copy: 376.5149 0.0171 0.0170 0.0174
Scale: 352.6559 0.0182 0.0181 0.0184
Add: 419.2872 0.0230 0.0229 0.0232
Triad: 418.9944 0.0231 0.0229 0.0232
-------------------------------------------------------------
This system uses 8 bytes per DOUBLE PRECISION word.
-------------------------------------------------------------
Array size = 400000, Offset = 0
Total memory required = 9.2 MB.
Each test is run 10 times, but only
the *best* time for each is used.
-------------------------------------------------------------
Your clock granularity/precision appears to be 1 microseconds.
Each test below will take on the order of 16165 microseconds.
(= 16165 clock ticks)
Increase the size of the arrays if this shows that
you are not getting at least 20 clock ticks per test.
-------------------------------------------------------------
WARNING -- The above is only a rough guideline.
For best results, please be sure you know the
precision of your system timer.
-------------------------------------------------------------
Function Rate (MB/s) RMS time Min time Max time
Copy: 355.5753 0.0181 0.0180 0.0186
Scale: 349.0592 0.0184 0.0183 0.0185
Add: 402.3133 0.0240 0.0239 0.0242
Triad: 409.2246 0.0238 0.0235 0.0259
-------------------------------------------------------------
This system uses 8 bytes per DOUBLE PRECISION word.
-------------------------------------------------------------
Array size = 400000, Offset = 0
Total memory required = 9.2 MB.
Each test is run 10 times, but only
the *best* time for each is used.
-------------------------------------------------------------
Your clock granularity/precision appears to be 1 microseconds.
Each test below will take on the order of 16411 microseconds.
(= 16411 clock ticks)
Increase the size of the arrays if this shows that
you are not getting at least 20 clock ticks per test.
-------------------------------------------------------------
WARNING -- The above is only a rough guideline.
For best results, please be sure you know the
precision of your system timer.
-------------------------------------------------------------
Function Rate (MB/s) RMS time Min time Max time
Copy: 629.7973 0.0104 0.0102 0.0112
Scale: 615.9176 0.0105 0.0104 0.0105
Add: 609.3690 0.0159 0.0158 0.0163
Triad: 680.0793 0.0143 0.0141 0.0144
-------------------------------------------------------------
This system uses 8 bytes per DOUBLE PRECISION word.
-------------------------------------------------------------
Array size = 400000, Offset = 0
Total memory required = 9.2 MB.
Each test is run 10 times, but only
the *best* time for each is used.
-------------------------------------------------------------
Your clock granularity/precision appears to be 1 microseconds.
Each test below will take on the order of 16231 microseconds.
(= 16231 clock ticks)
Increase the size of the arrays if this shows that
you are not getting at least 20 clock ticks per test.
-------------------------------------------------------------
WARNING -- The above is only a rough guideline.
For best results, please be sure you know the
precision of your system timer.
-------------------------------------------------------------
Function Rate (MB/s) RMS time Min time Max time
Copy: 402.5410 0.0160 0.0159 0.0161
Scale: 392.9756 0.0164 0.0163 0.0165
Add: 615.2663 0.0158 0.0156 0.0159
Triad: 471.3044 0.0205 0.0204 0.0206
-- GINIT Technology GmbH stefan.haenssgen@ginit-technology.de Dr. Stefan U. Haenssgen phone: +49-721-96681-0 Technologiepark mobile: +49-172-7193-544 Emmy-Noether-Str. 11 fax: +49-721-96681-111 D-76131 Karlsruhe http://www.ginit-technology.de