Submission of Standard Stream Result Intel Nehalem EP 2.4GHz

From: Mark_Digicor <mark@digicor.com.au>
Date: Wed Apr 01 2009 - 00:42:55 CDT


Dear Dr. McCalpin,
I would like to submit the standard STREAM result of a Supermicro Intel Xeon Nehalem system.
Below is the system description and STREAM test Result.
Hope to see it being posted soon.
 
Best Regards.

Mark Han

DiGiCOR Pty Ltd.

System Description:
Motherboard: Supermicro X8DTi-F
CPU: Intel Nehalem EP
CPU Speed: 2.4GHz
CPU(s): 2 processors, 4 cores/processor
L3 Cache: 8MB (per processor)
Memory: 12GB DDR3-1066 (1GB x 12 DIMMs)
Operating System:
Windows 2008 (64bit)
STREAM pro/code:
http://www.cs.virginia.edu/stream/FTP/Contrib/StreamWin-32-64_distro.zip
Result:
C:\SupermicroMB>time /t
05:32 PM
 
C:\SupermicroMB>sleep.exe 5
 
C:\SupermicroMB>set MP_BLIST=0,1,2,3,4,5,6,7
 
C:\SupermicroMB>start /b /WAIT /HIGH stream5.8_omp-64.exe
-------------------------------------------------------------
STREAM version $Revision: 5.8 $
-------------------------------------------------------------
This system uses 8 bytes per DOUBLE PRECISION word.
-------------------------------------------------------------
Array size = 40000000, Offset = 0
Total memory required = 915.5 MB.
Each test is run 40 times, but only
the *best* time for each is used.
-------------------------------------------------------------
Number of Threads requested = 8
-------------------------------------------------------------
Printing one line per active thread....
Printing one line per active thread....
Printing one line per active thread....
Printing one line per active thread....
Printing one line per active thread....
Printing one line per active thread....
Printing one line per active thread....
Printing one line per active thread....
-------------------------------------------------------------
Your clock granularity/precision appears to be 2 microseconds.
Each test below will take on the order of 21684 microseconds.
   (= 10842 clock ticks)
Increase the size of the arrays if this shows that
you are not getting at least 20 clock ticks per test.
-------------------------------------------------------------
WARNING -- The above is only a rough guideline.
For best results, please be sure you know the
precision of your system timer.
-------------------------------------------------------------
Function Rate (MB/s) Avg time Min time Max time
Copy: 32099.9440 0.0200 0.0199 0.0201
Scale: 32076.1233 0.0200 0.0200 0.0201
Add: 31092.6819 0.0309 0.0309 0.0310
Triad: 31107.0364 0.0309 0.0309 0.0310
-------------------------------------------------------------
Solution Validates
-------------------------------------------------------------
 
C:\SupermicroMB>time /t
05:32 PM
 
C:\SupermicroMB>date /t
Tue 03/31/2009
 

Received on Wed Apr 01 09:05:57 2009